Safety limits and pump: the settings
Limits that stop a watering that would be wrong, and the settings for a pump that several zones share.
Routine Max Safety Runtime Cap
The longest a routine watering may run, in minutes, all pulses together. 103 minutes to start with, 10 to 900. A watering that would need longer is not run at all and you get a message: it usually means the flow rate is wrong. Very slow drippers or long gaps between waterings can need more: set it to a little above the biggest watering you expect (target ÷ flow rate). Check my setup says if it is too low for your settings.
Max Daily Irrigation Runtime (Safety Cap)
All valve time in a day together: both waterings, Water now and service runs. 240 minutes to start with. It catches a schedule that fires more often than meant. Lower it only for a strict water allowance, and keep it above a deep soak plus a routine watering.
Service Mode Auto-Off
How long the Service Mode switch keeps the valve open before it switches itself off and tells you. 30 minutes to start with. Raise it for flushing long lines or a long leak hunt. See Service runs and Service Mode.
Pump Low-Power Warning Threshold
Only with a pump power sensor. After the valve opens, ZoneFlow waits up to 45 seconds for the pump to draw at least this much. If it does not, you get a warning: a pump that runs dry, has lost its prime, or has an empty tank draws much less power than when it pumps water. Set it about 20-30 % below the pump's normal running power (look at the power sensor during a service run). It warns; it does not stop the watering.
Pump Preamble (Warm-Up Delay)
Seconds to wait after the zone gets the pump, before its valve opens. Use it if the pump needs a moment to build pressure. 0 to start with.
Pump Postamble (Settle Delay)
Seconds to wait after the valve closes, before the next zone on the same pump may start. It lets the pressure settle. 0 to start with.
Valve Overlap
Zones on a shared pump can open the next valve this many seconds (0 to 10) before the finishing zone's valve closes, so the pump never pushes against closed valves and the pipes do not bang. 0 means they take turns as before. 2 to 3 seconds is usually enough. See Multiple zones and shared pumps.
Longest Valve Open Time and My Valve's Own Timer
See Valve backup timer.