ZoneFlow

Service runs and Service Mode

Every zone has Service Run 1 / 5 / 10 / 15 min buttons and a Service Mode switch. Use them to check drippers, flush lines or find leaks.

What they do

  • Service Run buttons: run the valve for 1, 5, 10 or 15 minutes. The 15 minute button is handy for a longer flow-rate test.
  • Service Mode switch: keeps the valve on until you switch it off. It switches off automatically after 30 minutes by default, and sends a phone alert.

Safety and the schedule

Service runs go through the same safety path as a real cycle, including the lock, the shared pump and the watchdogs. They never count as watering, so the schedule does not move. Their minutes do count toward the daily safety cap.

Measuring your emitter flow rate

The flow-rate helper works this out in three ways: calculated from your emitters' rated output, measured with a flow meter, or measured by the litres a service run gives. For the last one, run a service run (the Service Run 5, 10 or 15 min button, where 15 minutes is the most accurate), catch or read the water with a bucket, a barrel or a water meter, then open Configure → Flow rate, choose to measure it by the litres a service run gives, and enter the minutes, the litres and the area. The Calibrate the flow rate button on the zone card does the same in one go. How to measure your irrigation flow rate with a bucket shows how. Either way, the emitter flow rate is the one number that must be right. The full steps are in Calibration.

Bench test with a service call

zoneflow.test_pulse (seconds, default 10) is a bench test that bypasses all gates. See Services.